Development and Validation of a Simple and Robust Bioanalytical Method to the Quantification of Tafamidis in Human Plasma using LC-MS/MS

Indian Journal of Pharmaceutical Education and Research

  • Shashipal Aitha1Department of Chemistry, School of Applied Science and Humanities, Vignan’s Foundation for Science, Technology and Research, Vadlamudi, Guntur, Andhra Pradesh, INDIA.
  • Subramani Devaraju2Department of Chemistry, Polymer Engineering Laboratory, PSG Institute of Technology and Applied Research, Neelambur, Coimbatore, Tamil Nadu, INDIA.
  • Kiran Kumar Tatapudi3Discovery Analytical R&D, Aragen Life Sciences Pvt. Ltd., Nacharam, Hyderabad, Telangana, INDIA.
  • Geereddy Mahesh Kumar Reddy3Discovery Analytical R&D, Aragen Life Sciences Pvt. Ltd., Nacharam, Hyderabad, Telangana, INDIA.
  • Tiruveedhula Somasekhar4Department of Humanities & Sciences, Vidya Jyothi Institute of Technology, Aziz nagar Gate, Chilkur Balaji Road, Himayat Sagar Rd, Hyderabad, Telangana, INDIA.

Volume 60 Issue 4s Pages s1716-s1723

DOI: 10.5530/ijper.20262396

Abstract

Objectives: Amyloid diseases are a rare class of disorders that have gained significant attention for therapeutic advancements. Among the key proteins implicated, transthyretin plays a central role in the progression and clinical symptoms of these diseases. Tafamidis, an approved therapeutic agent, has demonstrated considerable efficacy in mitigating symptoms associated with transthyretin-related amyloid conditions. Despite its clinical significance, robust bioanalytical methodologies for the accurate quantification of Tafamidis in biological matrices remain limited. Materials and Methods: This study focuses on the development and validation of a precise bioanalytical method to quantify Tafamidis in human plasma using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS). The method was calibrated over a range of 5-4000 ng/mL, with chromatographic separation performed using an isocratic mobile phase on a Gemini NX C18 column. Mass transitions were optimized at 307.400 → 262.400 for Tafamidis and 313.900 → 270.000 for Tafamidis-13C6. A liquid-liquid extraction approach ensured efficient recovery of Tafamidis from plasma. Results and Discussion: Validated per USFDA regulatory guidelines, the method demonstrated excellent precision, accuracy, and stability, with correlation coefficients exceeding 0.99 and recovery rates reaching 70%. Stability was confirmed for up to 10 days in matrix and aqueous samples. Conclusion: This robust, validated method offers high reliability and suitability for analytical applications and quantitative clinical investigations involving Tafamidis.

Keywords

  • Amyloid Diseases
  • Transthyretin
  • Protein
  • Method development
  • Method validation
IJOPP