Simultaneous Estimation of Cal DL-2-Hydroxy,4-methyl thio-butyrate and Ca-2-oxo3-phenyl Propionate in Alpha-Ketoanalogues Tablets by Validated RP-HPLC Method

Indian Journal of Pharmaceutical Education and Research

  • Shambo Panda1Department of Pharmaceutical Analysis, School of Pharmaceutical Sciences, Siksha O Anusandhan (Deemed to be University), Bhubaneswar, Odisha, INDIA., 2Department of Pharmaceutical Chemistry, Bharat Technology, Beltala, Uluberia, Howrah, West Bengal, INDIA.
  • Anindya Bose1Department of Pharmaceutical Analysis, School of Pharmaceutical Sciences, Siksha O Anusandhan (Deemed to be University), Bhubaneswar, Odisha, INDIA.
  • Biplab Debnath2Department of Pharmaceutical Chemistry, Bharat Technology, Beltala, Uluberia, Howrah, West Bengal, INDIA.
  • Rajarshi Nath2Department of Pharmaceutical Chemistry, Bharat Technology, Beltala, Uluberia, Howrah, West Bengal, INDIA.
  • Arijit Das3Department of Pharmacology, Bharat Technology, Beltala, Uluberia, Howrah, West Bengal, INDIA.
  • Somsubhra Ghosh4Department of Pharmaceutical Analysis. The Neotia University, School of Pharmacy, Sarisha, Diamond Harbour, West Bengal, INDIA.

Volume 58 Issue 3 Pages 925-930

DOI: 10.5530/ijper.58.3.101

Abstract

Introduction: Alpha-Ketoanalogues is a dietary supplement drug containing Calcium-DL- 2-hydroxy-4-(methylthio) butyrate (CHMTB) and Calcium-2-oxo-3-phenyl propionate (COPP) for the management of chronic renal disease. Objectives: In this study, a simple RP-HPLC method has been developed to simultaneously determine Calcium-DL-2-hydroxy-4-(methylthio) butyrate (CHMTB) and Calcium-2-oxo-3-phenyl propionate (COPP) in Alpha-Ketoanalogues Tablets. Materials and Methods: The compounds were separated in a single run using a Waters XBridge 250 mm x 4.6 mm C18 column with 5μm particle size and 130 Å pore size. Elution was carried out via gradient mode with the UV detector wavelength set at 210 nm. The mobile phase selected was a binary mixture of ammonium hydrogen sulphate buffer (pH 7.0) and acetonitrile at a 1.0 mL/min flow rate. Results: The retention time of CHMB and COPP was found to be about 7 min and 20 min, respectively. The chromatographic method shows detector linearity in 50-150% of the operating range with the square of correlation coefficient at 0.9998 and 0.9999 for these two compounds, respectively. The parentage recovery of both CHMB and COPP was within 98-102% range. The method validation was carried out per the USP (chapter 1225) and ICH guidelines (Q2-R2). The developed method was found to be specific, precise, linear, robust, and accurate. Conclusion: This method could be utilized to assay tablet formulation of CHMB and COPP during the in-process and finished product quality control.

Keywords

  • Alpha-Ketoanalogues
  • Chronic kidney disease
  • Chromatography
  • Method Validation
  • Simultaneous estimation
  • Formulation
IJOPP

Loading…