QbD Driven Method Development and Validation of Palbociclib by LC-MS/MS

Indian Journal of Pharmaceutical Education and Research

  • Sneha Thakur1Department of Pharmacognosy, St. Pauls College of Pharmacy, Hyderabad, Telangana, INDIA.
  • Kavali Sai Varsha2Department of Pharmaceutical Analysis, St. Pauls College of Pharmacy, Hyderabad, Telangana, INDIA.
  • Shankar Cheruku3Department of Pharmaceutical Sciences, School of Biotechnology and Pharmaceutical Sciences, Vignan’s Foundation for Pharmaceutical Education and Research, Hyderabad, Telangana, INDIA.
  • Uzma Tahniyath2Department of Pharmaceutical Analysis, St. Pauls College of Pharmacy, Hyderabad, Telangana, INDIA.
  • Mitta Chaitanya4Department of Pharmaceutical Analysis, Bojjam Narasimhulu Pharmacy College for Women, Hyderabad, Telangana, INDIA.
  • B Chaitanya4Department of Pharmaceutical Analysis, Bojjam Narasimhulu Pharmacy College for Women, Hyderabad, Telangana, INDIA.

Volume 61 Issue 1 Pages 411-422

DOI: 10.5530/ijper.20272262

Abstract

Background: Palbociclib, an oral active cyclin dependent kinase inhibitor, is used in the treatment of metastatic breast cancer with narrow index and variable pharmacokinetics, hence the need of sensitive optimized analytical approach with LC-MS/MS offering superior detection with QbD approach is innovative strategy. Aim: The present study investigation involves the development and validate a method for quantification of Palbociclib in bulk and solid dosage form using a QbD-driven approach. Materials and Methods: The method was optimized according to ICH guidelines and performed on a quadrapole triple mass spectrometer with positive reaction mode. Results: The UPLC-hyphenated MS method was simple, reproducible, and accurate, with inter and intra-day precision results less than 15% and analyte accuracy (96-102%). The extraction recovery rate was 85-102%, and the linearity over the concentration range was 0.0106 µg/mL and 0.0321 µg/mL, respectively compared to earlier methods. Also, there was less matrix interference with simple sample extraction. Conclusion: The results reveal the method developed and validated revealed sensitivity, linearity, accuracy, precision, selectivity and rapid analysis in less run time (<10 min) which can be applied in Quality control labs as per ICH guidelines as done by the QbD method.

Keywords

  • Analytical method development
  • ICH
  • LC-MS/MS
  • Metastatic Breast Cancer
  • NSCLC
  • Palbociclib
  • Quality control
IJOPP

Loading…